CEMS Analyser

CEMS Analyzers

ASC GULF provides optimized solutions for the monitoring and measurement of pollutants, including: SO₂, NOₓ, CO, CO₂, NH₃, O2, HCl, HF, THC, Mercury, and others.

Their systems are designed based on extensive experience and are built using three primary measurement technologies

1. Dilution Extractive System

  • Process: Sample is extracted and immediately diluted with zero air at the probe.
  • Advantages:
    • Eliminates the need for heat-traced sample lines.
    • Ideal for applications where sample integrity must be maintained with minimal hardware complexity.

2. Hot-Wet Extractive System

  • Process: Sample is extracted through a heated filter from the stack/duct.
  • Features:
    • Blow-back arrangement for high-dust environments.
    • Sample is transported via heat-traced lines to maintain temperature and prevent condensation.
    • Suitable for Pollutants that may condense or react in cooler temperatures

3. In-Situ Measurement System

  • Process: Analyzer is installed directly at the measurement point on the stack or duct.
  • Types:
    • Cross-Duct: Measures across the entire duct.
    • Probe-Type: Measures at a specific point.